四虎最新影院 I 美女一区二区在线观看 I av不卡在线看 I 冲田杏梨 av作品在线 I 亚洲爆乳无码专区 I 特大色一区 I av综合av I 成人在线视频中文字幕 I 日韩精品免费在线视频 I 一级片黄色大片 I 99久久久无码国产精品试看 I 国内黄色小视频 I 91亚洲视频在线观看 I a久久久久久 I 午夜爽爽爽男女免费观看hd I 欧美 成人 亚洲 动漫 另类 I 四虎影院2019 I 肉耽高h男男1v1 I 成年片黄色日本大片网站视频 I 亚洲小说综合网 I 污的网站 I 波多野结衣中文字幕久久 I 又粗又猛又大爽又黄老大爷5 I 国产日产suv精品一区二区6 I 最新国产成人无码久久 I 欧美日韩一区二区精品 I 国产一区内射最近更新 I 巨粗进入警花哭喊求饶在线观看 I 污污网站观看 I 69国产精品成人 I 天堂а√中文最新版在线 I 2019精品视频 I 高贵麻麻被调教成玩物 I 精品国产精品网麻豆系列 I 韩国午夜小视频

網站公告-NOTICE
聯系我們
濟南航豐實業有限公司

電話:15168870138
聯系人:龐經理

網址:http://m.zkhtkj.cn  

廠址: 德州市禹城市莒鎮產業園26棟

經銷商地址:天橋區建華五金市場東區5-1  

魯ICP備09095923號-1

新聞資訊

當前位置:首頁 / 新聞資訊

濟南電纜橋架: 橋架間距應該如何設置?

  電纜橋架水平安裝時,支吊架之間距離適合在1.5米~2米,在轉彎處的支吊架間距應為0.3米~0.6米,垂直安裝電纜橋架時,支吊架間的距離不應該超過2米。下面由濟南航豐實業的小編給大家介紹一下安裝電纜橋架間距要求的相關內容。

When installing cable trays horizontally, the distance between supports and hangers should be suitable between 1.5 to 2 meters. The distance between supports and hangers at turns should be between 0.3 to 0.6 meters. When installing cable trays vertically, the distance between supports and hangers should not exceed 2 meters. Below, the editor from Jinan Hangfeng Industry will introduce the relevant content on the spacing requirements for installing cable trays.

  電纜橋架與一般工藝管道平行鋪設時,敷設間隔少400毫米,與工藝管道交叉敷設時,安裝間距小為300毫米,電纜橋架與腐蝕氣體管道的平行間距少為500毫米,交叉間距小為500毫米。電纜橋架水平安裝時,應該按照載荷規范選擇支、吊架間距,距離不應該大于2米。電纜橋架支、吊架的間距也要參考其產品性能參數說明來設置。

When the cable tray is laid parallel to the general process pipeline, the laying interval should be at least 400 millimeters. When cross laid with the process pipeline, the installation interval should be at least 300 millimeters. The parallel spacing between the cable tray and the corrosive gas pipeline should be at least 500 millimeters, and the cross spacing should be at least 500 millimeters. When installing cable trays horizontally, the spacing between supports and hangers should be selected according to the load specifications, and the optimal distance should not exceed 2 meters. The spacing between cable tray supports and hangers should also be set according to the product performance parameter specifications.

20210330042649173.png

  單層電纜橋架安裝時,配套支吊架的間距不應該大于2米,電纜橋架多層同時敷設時,支吊架之間的距離應該根據載荷進行具體計算。電纜橋架與無保溫的熱力管道水平敷設時,平行間距少為1米,交叉鋪設時的小間距應為0.5米,電纜橋架與有保溫措施的熱力管道交叉敷設時距離小為300毫米,水平鋪設時距離少為500毫米。

When installing single-layer cable trays, the spacing between supporting brackets should not exceed 2 meters. When laying multiple layers of cable trays simultaneously, the distance between brackets should be calculated specifically based on the load. When cable trays are horizontally laid with uninsulated thermal pipelines, the parallel spacing should be at least 1 meter, and the minimum spacing when cross laid should be 0.5 meters. When cable trays are cross laid with insulated thermal pipelines, the minimum distance is 300 millimeters, and when horizontally laid, the distance is at least 500 millimeters.

  本文由 濟南電纜橋架 友情奉獻。更多有關的知識請點擊: http://m.zkhtkj.cn 真誠的態度,為您提供為的服務。更多有關的知識我們將會陸續向大家奉獻,敬請期待。

This article is dedicated to the friendship of Jinan cable tray. For more information, please click on: http://m.zkhtkj.cn Sincere attitude, providing you with comprehensive service. We will gradually contribute more relevant knowledge to everyone, please stay tuned.

 
qq
售前咨詢熱線
15168870138
售后咨詢熱線
13465410318